For EI cores with spacers between the E and I pieces, apparent permeability is calculated using:
μapp = μmaterial / (1 + (lgap/lc) × μmaterial)
Where:
- μmaterial = ungapped permeability of the core material
- lc = magnetic path length (6 × tongue for standard EI)
- lgap = total magnetic gap = 2 × spacer thickness + 0.08 mm
— the flux crosses the gap twice, once from E to I and once from I back to E, and the butt
joint leaves a residual gap of its own even with no spacer fitted
Material values used:
- M6 (GOES) — grain-oriented electrical steel, μ ≈ 30,000
- M19 (NOES) — non-oriented electrical steel, μ ≈ 6,000
- M27 (NOES) — non-oriented, slightly less silicon, μ ≈ 5,000
- 49 % nickel — AL4750 and similar, μ ≈ 45,000
- 80 % nickel — mumetal, permalloy, μ ≈ 150,000
These are representative figures at moderate flux, shared with the
choke calculator so the two agree. Relative permeability is
not a single number — it swings by an order of magnitude with flux level, anneal and rolling
direction — but as the note below says, the gap decides μapp in any practical build, so
the choice barely reaches the answer.
This is capacity, not a design. Each cell is the most turns that will fit
inside the fill limit, and the inductance that follows. The
choke calculator asks the opposite question — how many
turns a target inductance needs — so the two will not print the same number for the same core
even though they now share their materials, their 6T path and their gap treatment, joint
residual included.
Where they meet is worth checking. On an EI-87 with a 1″ stack, M19 and a 14 mil
spacer, both put μ
app at 164. This page then fits 186 turns of 19 AWG at an
85 % limit, six whole layers, for 28.7 mH. The choke calculator needs 206 turns to
reach 35 mH, which is seven layers and 85.3 % — just past the limit set here. Raise
the fill limit to 86 % and this page fits the seventh layer too. Layers are whole numbers,
so a percent either way moves a whole layer.
Note: For practical gap sizes (>5 mil), the gap dominates and the formula simplifies to μapp ≈ lc/lgap regardless of material. Material choice matters more for small gaps where the core's intrinsic permeability becomes significant.
Why μapp varies by core size: Larger cores have longer magnetic paths (lc), so the same gap produces a higher μapp. In gap mode, the matrix calculates μapp individually for each core (shown in the left column). The "Reference Core" selector just controls which value is displayed in the green box above.
Random Winding Factor: Accounts for imperfect wire packing when hand-winding coils.
With perfect machine winding, each layer is exactly one wire diameter thick. Hand winding produces gaps, crossovers, and slight misalignment that increase the effective height of each layer.
Typical values:
- 1.0 — Perfect layer winding (machine wound or very careful technique)
- 1.1–1.15 — Good hand winding with attention to layer alignment
- 1.2–1.3 — Loose or scramble winding with significant gaps
The factor multiplies wire diameter to get effective layer height: Layer height = Wire diameter × Random factor
Circular Mils per Amp (CM/A): A measure of current-carrying capacity based on wire cross-sectional area.
Circular mils = (bare wire diameter in mils)². For example, 20 AWG (32 mils) = 1,024 circular mils.
Typical CM/A guidelines for magnet wire:
- 500–700 CM/A — Continuous duty, enclosed, limited cooling
- 300–500 CM/A — Intermittent duty or well-ventilated
- <300 CM/A — May overheat in continuous operation
The CM/A values shown in the table headers update based on your DC Current input, helping you verify wire sizing is appropriate for your application.
DCR and Power Loss: Each cell shows DC resistance and power dissipation at the specified current.
Calculations:
- MLT = 2(T + D + 2t) + π(hbuild/2) — where t = 0.0625" bobbin wall
- Wire length = MLT × Turns
- DCR = Wire length × Resistance per foot (from bare wire diameter)
- Power = I² × R
Blue values show DCR in ohms. Amber values show power dissipation in watts at the specified DC current.